CellCut

Laser Microdissection for highest sample integrity: MMI CellCut

The MMI CellCut facilitates precise and contamination-free dissection of cell clusters, single cells or subcellular compartments from various types of tissues including fresh frozen, paraffin-embedded and archived slides, cytospins, smears and even living cells.

YouTube

By loading the video, you agree to YouTube’s privacy policy.
Learn more

Load video

Your Benefits


Gentle to Cells
CellCut ensures the highest sample integrity by airtight and sterile cutting and collection. This will make your downstream applications more efficient to achieve reproducible results.


Cut it Clean
CellCut has the most precise cutting performance on the market. This ensures the thinnest and cleanest cut. Your sample will be not degraded.


Keep it Flexible
CellCut is the most flexible laser capture microdissection system. Compatible with many microscopes and almost all objective lenses. Update your laser microdissection system to produce Whole Slide Images with CellScan.

Check your Efficiency
In contrast to systems that use gravity for collection, CellCut enables a visual inspection and documentation of cut samples. Always check your cutting efficiency.  


Cut it All
You can cut almost any type of sample, such as fresh frozen tissue, FFPE material, plant tissue, smears, cytospins and living cells. Even the cutting of large areas beyond the field of vision is no problem.


Cut them Alive
Dissect living cells without removing culture media to ensure highest cell integrity for re-cultivation, cloning and single cell analysis.

Laser Microdissection from the Experts – Revolutionize your Research


With over 20 years of experience in laser microdissection, we at Molecular Machines & Industries make the difference. Our team of passionate researchers have developed the most precise laser microdissection system on the market. The gentle cutting guarantees a homogeneous cell population for meaningful downstream analysis.

The contamination-free cutting with full visual inspection at any step during and after isolation enables outstanding single cell cutting performance.

The MMI CellCut is highly modular and can be mounted on numerous brands of microscopes, from entry-level, mid-range to high-end instrumentation, suitable for routine applications as well as most complex research projects.

How can we support your project?


Asif Khan

David Hitrys

Ashley Remy

MMI CellCut microdissection

Dissection Perfection


The most gentle microdissection

Isolate your sample without any degradation and ensure meaningful downstream analyses in genomics, transcriptomics, proteomics, lipidomics and metabolomics. The cleanest laser microdissection on the market is enabled by the maintenance-free MMI laser. The low pulse energy laser (less than 500 ps) creates a very precise cutting edge (up to 0.3 µm) and therefore protects the surrounding area and biological information (RNA, DNA, Proteins).   


Move the stage and your laser is always in focus

By moving the stage and not the laser we ensure that the laser beam is always in focus. Other laser microdissection systems which move the laser can only cut samples in the field of view – leading to inaccurate cutting results.

  • Most accurate and precise cutting system on the market
  • No sample degradation for meaningful downstream applications
Principle of the MMI laser microdissection system

Visual Inspection of your Cells


Visual Inspection with the MMI CellCut Microdissection system

Where is my sample?

The MMI CellCut laser microdissection allows a full visual inspection of your sample during and after isolation. The unique MMI CapLift technology makes this possible. The CapLift technology uses an adhesive surface that keeps the sample in place during cutting. The orientation of the cell will be maintained, which allows you to easily verify the presence of the dissected area in the Isolation Cap. Furthermore, you can keep your sample in place during cutting to prevent single cells from flipping away. You will love this feature for your work on rare cells, and so will your reviewer!

  • Always check your cutting efficiency
  • Gentle, contamination-free and highly efficient sample collection with MMI CapLift technology
  • Gravity is not used for collection (Gravity allows no sample inspection and can damage the collected sample)

Have a look how it works

In the following video you will see how to select cells of interest, how to cut them and how you verify the successful collection


YouTube

By loading the video, you agree to YouTube’s privacy policy.
Learn more

Load video

Cut it all


Microdissection for almost any type of sample

With the MMI CellCut, you can dissect fresh frozen tissue, FFPE material, plant tissue, living cells, smears, cytospins and more.

 

Thick tissue is no problem

Do you need to cut thick or wet tissue? No problem! The “Z-drill feature” allows to refocus the laser on different z-levels. Therefore, you minimise the use of excessive laser power and so preserve your sample and maximize its usability for downstream analysis. An alternative high-power laser is available to cut very hard materials such as teeth, bones or forensic tapes.

 

Size does not matter

Dissect single cells or huge tissue areas – even beyond the field of vision. The precise laser is fixed while the stage is moving during laser cutting, thus the laser will always be in perfect focus, even with larger tissue areas.

Microdissection for any type of sample

Gotcha! MMI CapSure technology captures cells like a “ninja"


CapSure Technology from MMI

Enhancing precision in sample collection

The MMI laser capture microdissection system used the patented CapSure technology for the precise and contamination-free isolation of specific cells or regions of interest from tissue samples. The CapSure technology used a small adhesive cap, which automated the transfer of the target sample from the slide into a microcentrifuge tube (Isolation Cap). The Isolation Cap only gets into contact with the membrane – the sample itself is not touched. Therefore the sample can be handled free of contamination.

The gentle cutting and the transfer without unnecessary induction of physical or chemical forces leads to meaningful results for any downstream applications.

  • With CapSure you can always check your cutting efficiency
  • Contamination-free cutting
  • Gentle transfer of cut samples to ensure meaningful downstream applications

Boost Your Microdissection Efficiency


MMI CellCut with a MultiSlide

Predefined Target Positioning
The Predefined Target Positioning (PTP) feature allows a contamination-free and controlled collection of individual cells on the Isolation Cap. PTP is excellent to maximize the number of samples collected into a single reaction tube, guarantees isolated samples are not compromised by subsequent cutting and is essential for auditability.


MMI MultiCap and MultiSlide
The MMI MultiSlide enables you to process multiple samples in a single run, saving time and increasing efficiency in the laser microdissection workflow. You can isolate single cells into up to eight individual caps without the need to reload. The MultiSlide can also be used to analyze multiple regions within a single sample, allowing for a more comprehensive analysis of tissue or cell heterogeneity.

Applications


Cut them Alive


Live cell cutting without removing culture media

Isolate living cells to obtain a homogeneous live-cell population. In contrast to systems, that use upright microscopes, our laser comes from below. Therefore, you can dissect living cells without removing culture media to ensure highest cell integrity for meaningful -omics applications and re-cultivation.

 

Attach a climate chamber
You can equip the MMI CellCut with a climate chamber with full environmental control

  • Gentle living microdissection for meaningful downstream applications
  • Attach a climate chamber to the LMD system
  • Grow living cells on petri dishes with PEN membrane or multi-well ibidi slide
Living Cell Cutting with the MMI CellCut

Become an Expert in 10 min


Cutting a cell with the MMI CellCut microdissection system

MMI CellTools: The user-friendly solution for your microdissection

With CellCut you will be familiar within minutes. The intuitive CellTools software provides a user-friendly interface for controlling the microscope and the microdissection instrument for capturing cells of interest. Additionally, CellTools offer tools for annotating and labelling regions of interest, as well as for tracking and managing captured cells. Cutting cells was never so easy.

  • Control laser and microscope
  • Select regions for cutting by mouse or pen screen
  • Fully auto documentation for every cutting step (images & videos)
  • Import your ROIs from other devices (e.g. slide scanners)

Keep it flexible


Customize your microdissection

Customization is key for your research! The MMI CellCut is compatible with almost all microscopes and objective lenses – perfect for unique applications.

You can integrate our laser microdissection system on a confocal microscope, or you can combine it with Raman spectroscopy. For live cell applications, you can also integrate the system into an incubation hood.

Furthermore, the CellCut is compatible with all MMI single cell solutions (MMI CellScan, MMI CellEctor, MMI CellDetector and MMI CellManipulator)

  • You can use almost all inverted/confocal microscopes and objective lenses
  • Compatible with all other MMI Single Cell solutions
MMI CellCut is compatible with all objective lenses

Laser Microdissection meets Whole Slide Imaging


Microdissection meets Whole Slide Imaging

Whole slide imaging and beyond
Laser capture microdissections with the MMI CellCut can easily be combined with the MMI CellScan – a whole slide scanner to scan full-resolution digital slides. Combining laser microdissection with whole slide imaging (WSI) allows researchers to image a tissue section and then precisely select cells and dissect the tissue while concurrently preserving information about the original uncut tissue and position information about the cut. Thus, laser microdissection will be easily integrated into your digital pathology workflows.

  • Improve efficiency in pathology diagnostics and research by combining microdissection with whole slide imaging
  • Reduces hands-on time at the instrument by analysing your digital slides remotely

Read more about the MMI whole slide scanner

High-quality Consumables


Membrane Slides

  • PET Membrane Slides (RNAse free version available)
  • PPS Membrane Slides for lower autofluorescence
  • Fluoro Membrane Slides for ultra-low autofluorescence
  • Support Slide to support the transfer from a cryo section to a Membrane Slide

Membrane Slides for live cell laser microdissection

  • 18-well Membrane Slide
  • LiveCell Chamber

Tubes for contamination-free collection

  • Different sizes (single tubes or strips)
  • Diffuser caps for stained samples
  • Transparent caps for fluorescent samples
Consumables for MMI CellCut
Peng Guangdun

“I have compared all current available LMD platforms thoroughly and I got to say the CellCut plus is the most impressive one and I highly recommend it to our colleagues. Thanks for bring it to me.”

Dr. Guangdun Peng Guangzhou Institutes of Biomedicine and Health
Chinese Academy of Sciences
Guangzhou, China

“We appreciate the resistant MMI product quality, the professional consulting, and the competent and quick service. MMI instruments are an important basis for our in-situ analysis in cellular tissue. The MMI CellCut laser microdissection followed by gene expression analysis is complementary for further routine methods like conventional optical microscopy (fluorescence), in-situ hybridization, and immunohistochemistry.”

Prof. Dr. med. Danny D. Jonigk FRCPath Pathological Institute
Hannover Medical School
Hanover, Germany

Application Notes on the MMI CellCut – Download now


Living Cells for Omics Analysis


Microscopic Single Cell Isolation

Development of Novel Biomarkers

Molecular profiling

Living Cells for Re-cultivation


Selective Isolation

RNA seq on microdissected neurons


RNA analysis using microdissected lung tissue


Application Note - RNA analysis using microdissected lung tissue

The MMI CellCut provides a fully auditable and automatically documented workflow:

1. Prepare your sample

The section is placed on the MMI MembraneSlide, a frame slide covered with a thin membrane that is inert and has negligible autofluorescence. Afterwards, the MMI MembraneSlide is inverted and placed onto a glass slide for protection against contamination. Now the sample is sandwiched between the membrane and the glass.

2. Select your cells – any size and flexible shapes

The cells of interest can be selected quickly and easily using the MMI CellTools software. The touch screen enables straightforward selection of one or multiple spots, either using the interactive pen or using the mouse, by freehand or with predefined geometrical shapes. The stage is moving to trace the path drawn while the laser is fixed and focused from below.

3. Excise your cells – automatically and with sub-micron precision

The thin laser cutting path enables a precise and gentle extraction of the selected cell at an outstanding speed.

4. Collect your cells – full visual sample inspection after cutting

The isolated target cell is collected by lowering and lifting of the adhesive MMI IsolationCap held from above. The sample morphology remains 100% intact. After cutting, the sample can be visually inspected on the cap. Just add some buffer and invert the tube to suspend your cells for downstream processing.

Look at how your peers are using the MMI CellCut:

We’re here to help – please feel free to contact us!


Contact us.

Head Office Germany

Molecular Machines and Industries GmbH

Breslauer Strasse 2

D – 85386 Eching


+49 89 319 048 40


3