Consumables

For Precise Single Cell Isolation

Consumables for LMD

For contamination-free isolation of single cells or larger regions of interest (ROIs) using the LMD CellCut, specialised membrane slides with a thin membrane are required, onto which the tissue (e.g. FFPE samples) is mounted. ROI are then isolated into single tubes, strips, or 96-well plates. 

Membrane Slides and Rings 

Sticky Slides (PET)

Sticky Slides (PET)

  • Membrane slides with PET membrane (1.4 μm) 
  • Enhanced stickiness for easier sample mounting 
  • Compatible with all common tissue staining techniques 
  • Fully compatible with standard autoclaving procedures 
Sticky Slides (PET) - RNAse free

Sticky Slides (PET) - RNAse free

  • Membrane slides with PET membrane (1.4 μm) 
  • RNAse-free, nucleic acid-free
  • Enhanced stickiness for easier sample mounting 
  • Compatible with all common tissue staining techniques 
  • Fully compatible with standard autoclaving procedures 
Sticky Slides (PPS) 

Sticky Slides (PPS) 

  • Membrane slide with PPS membrane (1.2 μm)
  • Low autofluorescence
  • Enhanced stickiness for easier sample mounting
  • Compatible with all common tissue staining techniques
  • Fully compatible with standard autoclaving procedures 
Support Slide

Support Slide

  • Supports the transfer process from a cryo section to a Membrane Slide/Sticky Slide 
  • Give rigidity to the membrane during sample preparation
18-well Membrane Slide

18-well Membrane Slide

  • PEN membrane, 2 μm 
  • Living cell isolation without removing culture media  
Membrane Rings

Membrane Rings

  • Offered in PEN or PET membrane
  • Living cell isolation without removing culture media
  • For the recultivation of cells
Isolation Dish

Isolation Dish

  • Living cell isolation without removing culture media 
  • For the recultivation of cells 

96-Well Plate & Tubes

96-well Isolation Plate

96-well Isolation Plate

  • For high-throughput isolation
  • Silicone-bottom 96-well plate
  • Designed for MMI CellCut HT 
Isolation Caps (diffusor caps)

Isolation Caps (diffusor caps)

  • Tubes in 0.2 ml, 0.5 ml, and 1.5 ml sizes
  • Optimised for stained samples: highlights cores, minimises contrast of the cell wall
  • Protein low bind version available
Isolation Caps (transparent caps)

Isolation Caps (transparent caps)

  • Tubes in 0.2 ml, 0.5 ml, and 1.5 ml sizes 
  • Optimised for fluorescent samples: makes cell walls and tissue structures clearly visible 
  • Protein low bind version available  
     
CapStrips

CapStrips

  • 8-well Tube Strips, 0.2 ml
  • Available with transparent or diffuser caps

Consumables for Cell Picking

For gentle isolation of single cells in suspension using the CellEctor, various capillaries with different diameters, as well as different slides, well plates and nanowell slides are available.

Capillaries

Bent Capillaries

Bent Capillaries

  • Available in the following diameters: 20, 30, 40, 80, 120 and 160 μm 
  • Borosilicate microcapillaries  
  • Capillaries are bent to allow single cells to be isolated directly from above at a 90° angle 

Slides, Plates & Tubes 

CellEctor μ-Sides

CellEctor μ-Sides

  • 8-well, 18-well or 96-well slides
  • Enhance liquid handling efficiency on the MMI CellEctor 
8-well Tube Strips

8-well Tube Strips

  • 8-well Tube Strips, 0.2 ml
  • For the collection of cells in up to 8 different tubes 
SIEVEWELL Nanowells

SIEVEWELL Nanowells

  • Generate high-density cell arrays
  • Capture single-cells at a high rate
  • 90,000 or 370,000 nanowells
  • 20 or 50 μm nanowell size